Components

Construction assembly F0105

Lignum ID-№
F0105
Catalog number
F.1.05.DE625E
Source of construction assembly
Tschopp, Year 2017
Base structure
Ribs / rafters
Sheathing
without sheathing
Paneling
Simple covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
615 mm
Weight
255 kg/m2
U-value
≈ 0.102 W/m2K
GWP
179.00 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of ribs / rafters with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². without sheathing, . Simple covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
Ctr -7 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Garden plates Generic product 40 mm 96 kg/m2 - - 02.007 91.136
Use and protection layer 2 Gravel 8-16mm Generic product 40 mm 59.2 kg/m2 - - 03.011 91.062
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Exterior insulation layer 1 Mineral wool Generic product 60 mm 1.2 kg/m2 - - 10.008 91.173
Separating layer / temporary roof Vapor-permeable barrier Generic product 10 mm 3.9 kg/m2 - - 09.006 91.149
Bond no composite action - - - - - - -
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 380 mm 12.2 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Vapor barrier Moisture-adaptive vapor barrier Generic product 1 mm 1.5 kg/m2 - - 09.002 91.037

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 28 30 32 34 35 34 37 43 51 58 64 71 78 84 89 95 101 107 110 110 110 110
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 53 54 55 56 58 62 62 59 54 50 46 43 39 36 34 31 28 25 22 19 14 9

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
266659.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
170698.9
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
96041
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1347.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1322.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
754.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
569.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
24.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
631.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
630.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
358.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
270.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
717.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
693.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
395.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
298.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
23.1
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
179
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
93.7
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
85.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
86.90
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
23.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)