E0125
|
Ribs / rafters |
249
mm
|
51
dB
|
|
Insulation between and on supporting structure with covering |
93
kg/m2
|
-3
dB
|
Verified calculation |
≈
0.129
W/m2K
|
-10
dB
|
Detail
IFC4 LOD300
|
E0130
|
Ribs / rafters |
249
mm
|
52
dB
|
|
Insulation between and on supporting structure with covering |
103
kg/m2
|
-3
dB
|
Verified calculation |
≈
0.13
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
|
E0135
|
Solid wood panel |
419
mm
|
50
dB
|
|
Insulation on supporting structure |
112
kg/m2
|
-2
dB
|
Verified calculation |
≈
0.182
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0136
|
Solid wood panel |
474
mm
|
55
dB
|
|
Insulation on supporting structure with covering |
125
kg/m2
|
-3
dB
|
Verified calculation |
≈
0.151
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
|
E0137
|
Solid wood panel |
489
mm
|
57
dB
|
|
Insulation on supporting structure with covering |
136
kg/m2
|
-2
dB
|
Verified calculation |
≈
0.15
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0139
|
Solid wood panel |
494
mm
|
59
dB
|
|
Insulation on supporting structure with covering |
283
kg/m2
|
-5
dB
|
Verified calculation |
≈
0.141
W/m2K
|
-13
dB
|
Detail
IFC4 LOD300
|
E0140
|
Solid wood panel |
509
mm
|
63
dB
|
|
Insulation on supporting structure with covering |
294
kg/m2
|
-4
dB
|
Verified calculation |
≈
0.139
W/m2K
|
-11
dB
|
Detail
IFC4 LOD300
|
E0147
|
BRESTA Solid Timber System, planked on one side |
237
mm
|
36
dB
|
|
Insulation between the supporting structure |
106
kg/m2
|
-1
dB
|
Calculation |
≈
0.191
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0148
|
Ribs / rafters |
237
mm
|
37
dB
|
|
Insulation between the supporting structure |
111
kg/m2
|
-1
dB
|
Calculation |
≈
0.17
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0149
|
Ribs / rafters |
237
mm
|
38
dB
|
|
Insulation between the supporting structure |
115
kg/m2
|
-1
dB
|
Calculation |
≈
0.152
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0150
|
Ribs / rafters |
237
mm
|
39
dB
|
|
Insulation between the supporting structure |
124
kg/m2
|
-1
dB
|
Calculation |
≈
0.127
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0151
|
Ribs / rafters |
237
mm
|
40
dB
|
|
Insulation between the supporting structure |
133
kg/m2
|
-1
dB
|
Calculation |
≈
0.108
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0152
|
Ribs / rafters |
237
mm
|
49
dB
|
|
Insulation between the supporting structure |
100
kg/m2
|
-1
dB
|
Calculation |
≈
0.182
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0153
|
Ribs / rafters |
237
mm
|
51
dB
|
|
Insulation between the supporting structure |
103
kg/m2
|
-1
dB
|
Calculation |
≈
0.158
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0154
|
Ribs / rafters |
237
mm
|
52
dB
|
|
Insulation between the supporting structure |
107
kg/m2
|
-1
dB
|
Calculation |
≈
0.14
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0155
|
Ribs / rafters |
237
mm
|
54
dB
|
|
Insulation between the supporting structure |
113
kg/m2
|
-1
dB
|
Calculation |
≈
0.113
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0156
|
Ribs / rafters |
237
mm
|
56
dB
|
|
Insulation between the supporting structure |
118
kg/m2
|
-1
dB
|
Calculation |
≈
0.099
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0157
|
BRESTA Solid Timber System |
382
mm
|
49
dB
|
|
Insulation on supporting structure |
119
kg/m2
|
-2
dB
|
Calculation |
≈
0.216
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0158
|
BRESTA Solid Timber System |
422
mm
|
50
dB
|
|
Insulation on supporting structure |
124
kg/m2
|
-2
dB
|
Calculation |
≈
0.189
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0159
|
BRESTA Solid Timber System |
442
mm
|
50
dB
|
|
Insulation on supporting structure |
126
kg/m2
|
-2
dB
|
Calculation |
≈
0.177
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|