A0257
|
Ribs / joists |
500
mm
|
70
dB
|
45
dB
|
|
with dampening, floor construction and ceiling covering |
328
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.32
W/m2K
|
-8
dB
|
6
dB
|
Detail
IFC4 LOD300
|
A0258
|
Ribs / joists |
475
mm
|
67
dB
|
48
dB
|
|
with dampening, floor construction and ceiling covering |
262
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.321
W/m2K
|
-7
dB
|
5
dB
|
Detail
IFC4 LOD300
|
A0259
|
Ribs / joists |
465
mm
|
55
dB
|
60
dB
|
|
with dampening, floor construction and ceiling covering |
180
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.344
W/m2K
|
-4
dB
|
1
dB
|
Detail
IFC4 LOD300
|
A0260
|
Ribs / joists |
525
mm
|
80
dB
|
30
dB
|
|
with dampening, floor construction and ceiling covering |
500
kg/m2
|
0
dB
|
2
dB
|
Verified calculation |
≈
0.315
W/m2K
|
-9
dB
|
13
dB
|
Detail
IFC4 LOD300
|
A0261
|
Ribs / joists |
500
mm
|
80
dB
|
31
dB
|
|
with dampening, floor construction and ceiling covering |
434
kg/m2
|
-3
dB
|
4
dB
|
Verified calculation |
≈
0.316
W/m2K
|
-11
dB
|
14
dB
|
Detail
IFC4 LOD300
|
A0262
|
Ribs / joists |
490
mm
|
75
dB
|
40
dB
|
|
with dampening, floor construction and ceiling covering |
353
kg/m2
|
-4
dB
|
1
dB
|
Verified calculation |
≈
0.339
W/m2K
|
-8
dB
|
6
dB
|
Detail
IFC4 LOD300
|
A0263
|
Ribs / joists |
525
mm
|
80
dB
|
30
dB
|
|
with dampening, floor construction and ceiling covering |
490
kg/m2
|
-2
dB
|
4
dB
|
Verified calculation |
≈
0.311
W/m2K
|
-12
dB
|
16
dB
|
Detail
IFC4 LOD300
|
A0264
|
Ribs / joists |
500
mm
|
80
dB
|
33
dB
|
|
with dampening, floor construction and ceiling covering |
424
kg/m2
|
-6
dB
|
5
dB
|
Verified calculation |
≈
0.312
W/m2K
|
-14
dB
|
14
dB
|
Detail
IFC4 LOD300
|
A0265
|
Ribs / joists |
490
mm
|
73
dB
|
42
dB
|
|
with dampening, floor construction and ceiling covering |
343
kg/m2
|
-4
dB
|
1
dB
|
Verified calculation |
≈
0.334
W/m2K
|
-9
dB
|
7
dB
|
Detail
IFC4 LOD300
|
A0266
|
Ribs / joists |
510
mm
|
80
dB
|
32
dB
|
|
with dampening, floor construction and ceiling covering |
484
kg/m2
|
-4
dB
|
4
dB
|
Verified calculation |
≈
0.32
W/m2K
|
-15
dB
|
16
dB
|
Detail
IFC4 LOD300
|
A0267
|
Ribs / joists |
485
mm
|
80
dB
|
35
dB
|
|
with dampening, floor construction and ceiling covering |
418
kg/m2
|
-8
dB
|
5
dB
|
Verified calculation |
≈
0.321
W/m2K
|
-17
dB
|
15
dB
|
Detail
IFC4 LOD300
|
A0268
|
Ribs / joists |
475
mm
|
71
dB
|
44
dB
|
|
with dampening, floor construction and ceiling covering |
337
kg/m2
|
-4
dB
|
2
dB
|
Verified calculation |
≈
0.344
W/m2K
|
-9
dB
|
7
dB
|
Detail
IFC4 LOD300
|
A0293
|
Hollow box element |
130
mm
|
60
dB
|
55
dB
|
|
with floor construction |
221
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.336
W/m2K
|
-6
dB
|
3
dB
|
Detail
IFC4 LOD300
|
A0295
|
Hollow box element |
105
mm
|
57
dB
|
58
dB
|
|
with floor construction |
155
kg/m2
|
-4
dB
|
1
dB
|
Verified calculation |
≈
0.337
W/m2K
|
-6
dB
|
3
dB
|
Detail
IFC4 LOD300
|
A0297
|
Hollow box element |
95
mm
|
47
dB
|
68
dB
|
|
with floor construction |
74
kg/m2
|
-2
dB
|
0
dB
|
Verified calculation |
≈
0.363
W/m2K
|
-3
dB
|
1
dB
|
Detail
IFC4 LOD300
|
A0298
|
Hollow box element |
145
mm
|
62
dB
|
53
dB
|
|
with floor construction |
237
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.331
W/m2K
|
-6
dB
|
4
dB
|
Detail
IFC4 LOD300
|
A0300
|
Hollow box element |
120
mm
|
58
dB
|
57
dB
|
|
with floor construction |
171
kg/m2
|
-3
dB
|
0
dB
|
Verified calculation |
≈
0.331
W/m2K
|
-5
dB
|
3
dB
|
Detail
IFC4 LOD300
|
A0302
|
Hollow box element |
110
mm
|
49
dB
|
66
dB
|
|
with floor construction |
90
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.356
W/m2K
|
-3
dB
|
1
dB
|
Detail
IFC4 LOD300
|
A0303
|
Hollow box element |
185
mm
|
62
dB
|
53
dB
|
|
with floor construction and ceiling covering |
242
kg/m2
|
-3
dB
|
1
dB
|
Verified calculation |
≈
0.285
W/m2K
|
-6
dB
|
4
dB
|
Detail
IFC4 LOD300
|
A0305
|
Hollow box element |
160
mm
|
58
dB
|
57
dB
|
|
with floor construction and ceiling covering |
176
kg/m2
|
-3
dB
|
0
dB
|
Verified calculation |
≈
0.286
W/m2K
|
-5
dB
|
3
dB
|
Detail
IFC4 LOD300
|