Filter Catalog Flat roof / shed roof

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 4 of 5. There were 100 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

F0089

BRESTA Solid Timber System 719 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1404 kg/m2 -5 dB
Calculation ≈ 0.101 W/m2K -13 dB
Detail IFC4 LOD300

F0090

BRESTA Solid Timber System 759 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1405 kg/m2 -5 dB
Calculation ≈ 0.091 W/m2K -13 dB
Detail IFC4 LOD300

F0091

BRESTA Solid Timber System 819 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1406 kg/m2 -5 dB
Calculation ≈ 0.079 W/m2K -13 dB
Detail IFC4 LOD300

F0092

BRESTA Solid Timber System 899 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1408 kg/m2 -5 dB
Calculation ≈ 0.067 W/m2K -13 dB
Detail IFC4 LOD300

F0093

Ribs / rafters 230 mm 45 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 55 kg/m2 -1 dB
Calculation ≈ 0.571 W/m2K -5 dB
Detail IFC4 LOD300

F0094

Ribs / rafters 250 mm 46 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 56 kg/m2 -1 dB
Calculation ≈ 0.566 W/m2K -5 dB
Detail IFC4 LOD300

F0095

Ribs / rafters 270 mm 47 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 58 kg/m2 -1 dB
Calculation ≈ 0.562 W/m2K -5 dB
Detail IFC4 LOD300

F0096

Ribs / rafters 290 mm 48 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 60 kg/m2 -1 dB
Calculation ≈ 0.557 W/m2K -5 dB
Detail IFC4 LOD300

F0097

Ribs / rafters 310 mm 49 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 61 kg/m2 -1 dB
Calculation ≈ 0.553 W/m2K -6 dB
Detail IFC4 LOD300

F0098

Ribs / rafters 330 mm 49 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 63 kg/m2 -1 dB
Calculation ≈ 0.549 W/m2K -5 dB
Detail IFC4 LOD300

F0099

Ribs / rafters 350 mm 50 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 64 kg/m2 -1 dB
Calculation ≈ 0.544 W/m2K -5 dB
Detail IFC4 LOD300

F0100

Ribs / rafters 330 mm 51 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 66 kg/m2 -1 dB
Calculation ≈ 0.558 W/m2K -5 dB
Detail IFC4 LOD300

F0101

Ribs / rafters 181 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 232 kg/m2 -2 dB
Calculation ≈ 0.171 W/m2K -7 dB
Detail IFC4 LOD300

F0102

Ribs / rafters 181 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 236 kg/m2 -2 dB
Calculation ≈ 0.154 W/m2K -7 dB
Detail IFC4 LOD300

F0103

Ribs / rafters 181 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 240 kg/m2 -2 dB
Calculation ≈ 0.139 W/m2K -7 dB
Detail IFC4 LOD300

F0104

Ribs / rafters 181 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 247 kg/m2 -2 dB
Calculation ≈ 0.118 W/m2K -7 dB
Detail IFC4 LOD300

F0105

Ribs / rafters 181 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 255 kg/m2 -2 dB
Calculation ≈ 0.102 W/m2K -7 dB
Detail IFC4 LOD300

F0106

Ribs / rafters 258 mm 57 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between the supporting structure of covering 87 kg/m2 -6 dB
Calculation ≈ 0.184 W/m2K -14 dB
Detail IFC4 LOD300

F0107

Ribs / rafters 258 mm 59 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between the supporting structure of covering 91 kg/m2 -5 dB
Calculation ≈ 0.164 W/m2K -13 dB
Detail IFC4 LOD300

F0108

Ribs / rafters 258 mm 61 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between the supporting structure of covering 94 kg/m2 -5 dB
Calculation ≈ 0.148 W/m2K -13 dB
Detail IFC4 LOD300