Filter Catalog Flat roof / shed roof

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 1 of 5. There were 100 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

F0078

BRESTA Solid Timber System 516 mm 55 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Insulation on supporting structure 395 kg/m2 -2 dB
Calculation ≈ 0.129 W/m2K -6 dB
Detail IFC4 LOD300

F0039

BRESTA Solid Timber System 587 mm 41 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 148 kg/m2 -1 dB
Calculation ≈ 0.15 W/m2K -7 dB
Detail IFC4 LOD300

F0096

Ribs / rafters 290 mm 48 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 60 kg/m2 -1 dB
Calculation ≈ 0.557 W/m2K -5 dB
Detail IFC4 LOD300

F0119

Ribs / rafters 306 mm 65 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 109 kg/m2 -5 dB
Calculation ≈ 0.13 W/m2K -12 dB
Detail IFC4 LOD300

F0101

Ribs / rafters 181 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 232 kg/m2 -2 dB
Calculation ≈ 0.171 W/m2K -7 dB
Detail IFC4 LOD300

F0069

BRESTA Solid Timber System 639 mm 65 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1168 kg/m2 -5 dB
Calculation ≈ 0.103 W/m2K -11 dB
Detail IFC4 LOD300

F0055

BRESTA Solid Timber System 460 mm 44 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 117 kg/m2 -1 dB
Calculation ≈ 0.121 W/m2K -3 dB
Detail IFC4 LOD300

F0104

Ribs / rafters 181 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between and on supporting structure with covering 247 kg/m2 -2 dB
Calculation ≈ 0.118 W/m2K -7 dB
Detail IFC4 LOD300

F0117

Ribs / rafters 306 mm 60 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 100 kg/m2 -5 dB
Calculation ≈ 0.166 W/m2K -12 dB
Detail IFC4 LOD300

F0095

Ribs / rafters 270 mm 47 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 58 kg/m2 -1 dB
Calculation ≈ 0.562 W/m2K -5 dB
Detail IFC4 LOD300

F0106

Ribs / rafters 258 mm 57 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between the supporting structure of covering 87 kg/m2 -6 dB
Calculation ≈ 0.184 W/m2K -14 dB
Detail IFC4 LOD300

F0072

BRESTA Solid Timber System 819 mm 65 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1171 kg/m2 -5 dB
Calculation ≈ 0.068 W/m2K -11 dB
Detail IFC4 LOD300

F0077

BRESTA Solid Timber System 606 mm 47 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 135 kg/m2 -1 dB
Calculation ≈ 0.09 W/m2K -3 dB
Detail IFC4 LOD300

F0041

BRESTA Solid Timber System 707 mm 42 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 154 kg/m2 -1 dB
Calculation ≈ 0.11 W/m2K -7 dB
Detail IFC4 LOD300

F0085

BRESTA Solid Timber System 580 mm 70 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Insulation on supporting structure 509 kg/m2 -2 dB
Calculation ≈ 0.111 W/m2K -8 dB
Detail IFC4 LOD300

F0089

BRESTA Solid Timber System 719 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 1404 kg/m2 -5 dB
Calculation ≈ 0.101 W/m2K -13 dB
Detail IFC4 LOD300

F0094

Ribs / rafters 250 mm 46 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Rib/bar

Without insulation 56 kg/m2 -1 dB
Calculation ≈ 0.566 W/m2K -5 dB
Detail IFC4 LOD300

F0044

BRESTA Solid Timber System 476 mm 45 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 159 kg/m2 -2 dB
Calculation ≈ 0.116 W/m2K -6 dB
Detail IFC4 LOD300

F0109

Ribs / rafters 258 mm 65 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier

Insulation between the supporting structure of covering 102 kg/m2 -5 dB
Calculation ≈ 0.123 W/m2K -13 dB
Detail IFC4 LOD300

F0035

BRESTA Solid Timber System 290 mm 40 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 129 kg/m2 -1 dB
Calculation ≈ 0.335 W/m2K -3 dB
Detail IFC4 LOD300