E0174
|
Ribs / rafters |
562
mm
|
52
dB
|
|
Insulation on supporting structure |
96
kg/m2
|
-1
dB
|
Calculation |
≈
0.177
W/m2K
|
-6
dB
|
Detail
IFC4 LOD300
|
E0166
|
Ribs / rafters |
662
mm
|
44
dB
|
|
Insulation on supporting structure |
110
kg/m2
|
-3
dB
|
Calculation |
≈
0.108
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0130
|
Ribs / rafters |
249
mm
|
52
dB
|
|
Insulation between and on supporting structure with covering |
103
kg/m2
|
-3
dB
|
Verified calculation |
≈
0.13
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
|
E0164
|
Ribs / rafters |
542
mm
|
43
dB
|
|
Insulation on supporting structure |
96
kg/m2
|
-3
dB
|
Calculation |
≈
0.153
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0169
|
Ribs / rafters |
584
mm
|
51
dB
|
|
Insulation on supporting structure |
100
kg/m2
|
-1
dB
|
Calculation |
≈
0.142
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0135
|
Solid wood panel |
419
mm
|
50
dB
|
|
Insulation on supporting structure |
112
kg/m2
|
-2
dB
|
Verified calculation |
≈
0.182
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0160
|
BRESTA Solid Timber System |
502
mm
|
51
dB
|
|
Insulation on supporting structure |
133
kg/m2
|
-2
dB
|
Calculation |
≈
0.151
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0161
|
BRESTA Solid Timber System |
562
mm
|
51
dB
|
|
Insulation on supporting structure |
139
kg/m2
|
-2
dB
|
Calculation |
≈
0.131
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0094
|
Ribs / rafters |
196
mm
|
50
dB
|
|
Insulation between and on supporting structure with covering |
83
kg/m2
|
-4
dB
|
Verified calculation |
≈
0.143
W/m2K
|
-11
dB
|
Detail
IFC4 LOD300
|
E0147
|
BRESTA Solid Timber System, planked on one side |
237
mm
|
36
dB
|
|
Insulation between the supporting structure |
106
kg/m2
|
-1
dB
|
Calculation |
≈
0.191
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0165
|
Ribs / rafters |
602
mm
|
43
dB
|
|
Insulation on supporting structure |
103
kg/m2
|
-3
dB
|
Calculation |
≈
0.127
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0183
|
Ribs / rafters |
397
mm
|
48
dB
|
|
Insulation between the supporting structure of covering |
82
kg/m2
|
-4
dB
|
Calculation |
≈
0.147
W/m2K
|
-10
dB
|
Detail
IFC4 LOD300
|
E0170
|
Ribs / rafters |
644
mm
|
51
dB
|
|
Insulation on supporting structure |
108
kg/m2
|
-1
dB
|
Calculation |
≈
0.119
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0148
|
Ribs / rafters |
237
mm
|
37
dB
|
|
Insulation between the supporting structure |
111
kg/m2
|
-1
dB
|
Calculation |
≈
0.17
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0156
|
Ribs / rafters |
237
mm
|
56
dB
|
|
Insulation between the supporting structure |
118
kg/m2
|
-1
dB
|
Calculation |
≈
0.099
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0063
|
Ribs / rafters |
319
mm
|
50
dB
|
|
Insulation on supporting structure |
97
kg/m2
|
-2
dB
|
Verified calculation |
≈
0.226
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0149
|
Ribs / rafters |
237
mm
|
38
dB
|
|
Insulation between the supporting structure |
115
kg/m2
|
-1
dB
|
Calculation |
≈
0.152
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
E0171
|
Ribs / rafters |
704
mm
|
52
dB
|
|
Insulation on supporting structure |
115
kg/m2
|
-1
dB
|
Calculation |
≈
0.103
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
E0162
|
Ribs / rafters |
482
mm
|
41
dB
|
|
Insulation on supporting structure |
88
kg/m2
|
-3
dB
|
Calculation |
≈
0.192
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
E0184
|
Ribs / rafters |
417
mm
|
48
dB
|
|
Insulation between the supporting structure of covering |
84
kg/m2
|
-4
dB
|
Calculation |
≈
0.139
W/m2K
|
-10
dB
|
Detail
IFC4 LOD300
|