Filter Catalog Steep roof

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 1 of 4. There were 72 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0174

Ribs / rafters 562 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -1 dB
Calculation ≈ 0.177 W/m2K -6 dB
Detail IFC4 LOD300

E0166

Ribs / rafters 662 mm 44 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 110 kg/m2 -3 dB
Calculation ≈ 0.108 W/m2K -8 dB
Detail IFC4 LOD300

E0130

Ribs / rafters 249 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering below 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 103 kg/m2 -3 dB
Verified calculation ≈ 0.13 W/m2K -9 dB
Detail IFC4 LOD300

E0164

Ribs / rafters 542 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -3 dB
Calculation ≈ 0.153 W/m2K -8 dB
Detail IFC4 LOD300

E0169

Ribs / rafters 584 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 100 kg/m2 -1 dB
Calculation ≈ 0.142 W/m2K -5 dB
Detail IFC4 LOD300

E0135

Solid wood panel 419 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Insulation on supporting structure 112 kg/m2 -2 dB
Verified calculation ≈ 0.182 W/m2K -7 dB
Detail IFC4 LOD300

E0160

BRESTA Solid Timber System 502 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 133 kg/m2 -2 dB
Calculation ≈ 0.151 W/m2K -7 dB
Detail IFC4 LOD300

E0161

BRESTA Solid Timber System 562 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 139 kg/m2 -2 dB
Calculation ≈ 0.131 W/m2K -7 dB
Detail IFC4 LOD300

E0094

Ribs / rafters 196 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: no composite action
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 83 kg/m2 -4 dB
Verified calculation ≈ 0.143 W/m2K -11 dB
Detail IFC4 LOD300

E0147

BRESTA Solid Timber System, planked on one side 237 mm 36 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: Vapor barrier polyethylene (PE)
Lower skin 2nd layer: Bresta Solid timber panel

Insulation between the supporting structure 106 kg/m2 -1 dB
Calculation ≈ 0.191 W/m2K -7 dB
Detail IFC4 LOD300

E0165

Ribs / rafters 602 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 103 kg/m2 -3 dB
Calculation ≈ 0.127 W/m2K -8 dB
Detail IFC4 LOD300

E0183

Ribs / rafters 397 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Mineral wool
Vapor barrier: Vapor barrier polyethylene (PE)

Insulation between the supporting structure of covering 82 kg/m2 -4 dB
Calculation ≈ 0.147 W/m2K -10 dB
Detail IFC4 LOD300

E0170

Ribs / rafters 644 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 108 kg/m2 -1 dB
Calculation ≈ 0.119 W/m2K -5 dB
Detail IFC4 LOD300

E0148

Ribs / rafters 237 mm 37 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: Vapor barrier polyethylene (PE)
Lower skin 2nd layer: Bresta Solid timber panel

Insulation between the supporting structure 111 kg/m2 -1 dB
Calculation ≈ 0.17 W/m2K -7 dB
Detail IFC4 LOD300

E0156

Ribs / rafters 237 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Cavity dampening: Mineral wool
Lower skin layer 1: Vapor barrier polyethylene (PE)
Lower skin 2nd layer: Bresta Solid timber panel

Insulation between the supporting structure 118 kg/m2 -1 dB
Calculation ≈ 0.099 W/m2K -5 dB
Detail IFC4 LOD300

E0063

Ribs / rafters 319 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Sheathed above 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.

Insulation on supporting structure 97 kg/m2 -2 dB
Verified calculation ≈ 0.226 W/m2K -8 dB
Detail IFC4 LOD300

E0149

Ribs / rafters 237 mm 38 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: Vapor barrier polyethylene (PE)
Lower skin 2nd layer: Bresta Solid timber panel

Insulation between the supporting structure 115 kg/m2 -1 dB
Calculation ≈ 0.152 W/m2K -7 dB
Detail IFC4 LOD300

E0171

Ribs / rafters 704 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 115 kg/m2 -1 dB
Calculation ≈ 0.103 W/m2K -5 dB
Detail IFC4 LOD300

E0162

Ribs / rafters 482 mm 41 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 88 kg/m2 -3 dB
Calculation ≈ 0.192 W/m2K -8 dB
Detail IFC4 LOD300

E0184

Ribs / rafters 417 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥100kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Mineral wool
Vapor barrier: Vapor barrier polyethylene (PE)

Insulation between the supporting structure of covering 84 kg/m2 -4 dB
Calculation ≈ 0.139 W/m2K -10 dB
Detail IFC4 LOD300